DADOS ELETROCARDIOGRÁFICOS PADRÃO DE MACACOS-PREGO (Cebus apella, Linnaeus, 1758)

STANDARD ELECTROCARDIOGRAPHIC DATA FROM CAPUCHIN MONKEYS (Cebus apella, Linnaeus, 1758).

Home > CIÊNCIAS AGRÁRIAS > Imagens da Fauna: Diagnóstico por Imagem em Animais Silvestres - Avanços e Aplicações em Anatomia e Fisiologia Veterinária


Resumo:

Objetivo: caracterizar os traçados eletrocardiográficos de 12 macacos-prego jovens e saudáveis ??que foram contidos com cetamina e midazolam. Resultados: Todos os 12 macacos tinham ritmos sinusais normais. Nem a duração da onda P, intervalo PR, intervalo QT, nem a amplitude da onda P ou R (em milivolts) diferiram entre machos e fêmeas. As ondas P foram pequenas, monofásicas e positivas em todos os animais. O complexo QRS mostrou polaridade positiva nas derivações D1, D2, aVL, aVF, V2, V4 e V10 e polaridade negativa nas derivações D3, aVR e rV2. A onda T exibiu polaridade negativa apenas na derivação aVR em todos os animais do estudo, e nenhuma diferença significativa estava presente entre os sexos. O segmento ST era isoelétrico em ambos os sexos e não apresentava reduções nem elevações. Conclusão: O protocolo anestésico foi bem tolerado por todos os macacos e permitiu a aquisição, medição e caracterização de qualidade diagnóstica do eletrocardiograma e o estabelecimento dos parâmetros eletrocardiográficos normais de macacos-prego contidos quimicamente.


Palavra-chave: Eletrocardiograma;,Primatas não-humanos;,Ritmo cardíaco.


Abstract:

Objective: characterize the electrocardiographic tracings from 12 healthy, young capuchin monkeys that were restrained with ketamine and midazolam. Results: All 12 monkeys had normal sinus rhythms. Neither P-wave duration, PR interval, QT interval, nor P- or R-wave amplitude (in millivolts) differed between males and females. The P waves were small, monophasic, and positive in all animals. The QRS complex showed positive polarity in the D1, D2, aVL, aVF, V2, V4, and V10 derivations and negative polarity in the D3, aVR, and rV2 leads. The T wave exhibited a negative polarity only in the aVR derivation in all animals in the study, and no significant difference was present between sexes. The ST segment was isoelectric in both sexes and lacked reductions and elevations. Conclusion: The anesthetic protocol was well tolerated all of the monkeys and allowed for diagnostic-quality acquisition, measurement, and characterization of the electrocardiogram and establishment of the normal electrocardiographic parameters of chemically restrained capuchin monkeys.


Keywords: Electrocardiogram;,Non-human primates;,Heart rhythm.


Idiomas:


PORTUGUÊS

DOI:


10.48140/digitaleditora.2025.006.5

ISBN:


978-65-89361-32-9

AUTORES :


Fancisco das Chagas Araújo Sousa
André Braga de Souza
Caike Pinho de Sousa
Danielle Climaco Marques
José Luís de Sousa Santana
Eduardo Antonio Lima Oliveira
Marina Pinto Sanches
Rita de Cassia Viana
Ycaro Kylldary Macêdo
Rebeca Araújo Dias
Flávio Ribeiro Alves



Rua Luis Pires de Lima, 3770 – São João
Teresina – PI – CEP: 64.047-020
E-mail: [email protected]

Digital Editora - CNPJ: 37.684.427/0001-66

© 2025 - Digital Editora - Todos os direitos reservados.